High Throughput Bioreactor Incubator Shaker NHBIS-100 offers a capacity of 380 liters, accommodating multiple bioreactor vessels. It provides highly accurate temperature control with ±0.1°C precision, ensuring optimal conditions. This unit is built with a durable, high-borosilicate glass tank for long-term use. It features a high-quality AC induction motor for precise agitation. Our incubator shaker includes a 10-inch color touch screen for intuitive operation and monitoring.
$57,288.00
Specifications
| Capacity | 380 liters |
| Reactor tank material | High borosilicate glass tank |
| Reactor tank maximum capacity | 2000ml×6 1000ml×6 |
| Circulation method | Forced convection |
| Temperature accuracy | ±0.1°C |
| Temperature uniformity | ≤±1.0°C at 37°C |
| Temperature fluctuation | ≤±0.5°C |
| Rotation way | Rotary switchable |
| Rotation speed | 30 to 300 rpm |
| Rotation accuracy | ±1 rpm |
| Throw | 25 mm |
| Timing range | 0 to 500min |
| Display | 10-inch touch screen |
| UV lamp/fluorescent lamp | Yes |
| Workspace material | Stainless steel type 304 |
| Motor | Induction motor |
| Bearings | Imported double row bearings |
| Power supply | 220V±10%, 50/60Hz |
| Tray size | 710×480mm |
| Internal dimension | 880×550×785mm |
| External dimension | 1280×660×1440mm |
Features
Applications
Ask Expert
FAQ for High Throughput Bioreactor Incubator Shaker NHBIS-100
1: How reliable is the High Throughput Bioreactor Incubator Shaker NHBIS-100 for long-term use?
Our High Throughput Bioreactor Incubator Shaker is built with imported double-row bearings and molded ductile iron components, ensuring stability, low vibration, and long operational life. Customers can trust it for continuous, high-throughput bioprocessing without frequent maintenance.
2: Can the High Throughput Bioreactor Incubator Shaker NHBIS-100 be expanded or upgraded?
Our High Throughput Bioreactor Incubator Shaker supports modular expansion for advanced monitoring, including dissolved oxygen sensing, mass flow measurement, humidity monitoring, and light culture integration. This allows customization according to specific research or industrial needs.
3: Is the High Throughput Bioreactor Incubator Shaker energy efficient and quiet during operation?
The High Throughput Bioreactor Incubator Shaker uses a five-dimensional balance drive system and low-noise AC motor, providing energy-efficient and quiet operation. This ensures minimal disturbance in the laboratory environment while maintaining high performance.
4: How often should the High Throughput Bioreactor Incubator Shaker NHBIS-100 be cleaned?
The High Throughput Bioreactor Incubator Shaker should be cleaned after every batch to prevent contamination and maintain optimal performance. Customers can wipe the chamber and trays with a mild disinfectant and sterilize the glass tank using the built-in UV lamp or appropriate cleaning solutions.
5: What general tips ensure overall longevity?
Our High Throughput Bioreactor Incubator Shaker should be operated within the recommended temperature, speed, and load limits. Customers should follow routine inspections, clean regularly, and avoid sudden power interruptions to maintain optimal performance and safety.
6: Does the High Throughput Bioreactor Incubator Shaker ensure safety during operation?
Yes, the High Throughput Bioreactor Incubator Shaker is equipped with advanced safety features such as alarms and protective mechanisms. These safeguards help prevent overheating, system failures, or sample loss during extended runs.
7: Is the High Throughput Bioreactor Incubator Shaker easy to operate for new users?
The touch screen interface makes it user-friendly and intuitive, even for those with minimal training. It simplifies setup, allows easy monitoring of parameters, and ensures smooth operation without complexity.
8: Can this High Throughput Bioreactor Incubator Shaker handle delicate cultures that require precise conditions?
Yes, the precise temperature control and adjustable shaking speed make it ideal for sensitive cultures. It ensures stable and reproducible conditions, which are critical for delicate biological samples.
9: How should the High Throughput Bioreactor Incubator Shaker be cleaned after use?
The High Throughput Bioreactor Incubator Shaker should be cleaned with a soft cloth and mild disinfectant to remove any spills or residues. Care should be taken to avoid harsh chemicals or abrasive materials that could damage the surface or internal components.
Labnics High Throughput Bioreactor Incubator Shakers accommodate multiple vessels, flasks, or bioreactors for simultaneous culture growth. They maintain precise temperature control to ensure stable incubation and reproducible results. These units offer variable shaking speed with adjustable agitation for efficient oxygen transfer and mixing. They support high-throughput efficiency by processing multiple samples at the same time. Our systems include a touch screen interface for intuitive operation and real-time monitoring.