Dual Block Thermal Cycler NDBTC-100

Dual Block Thermal Cycler NDBTC-100

Dual Block Thermal Cycler NDBTC-100 accommodates two 48×0.2 ml tubes for flexible sample processing. It provides adjustable ramping rates between 0.1 and 5°C per second for precise temperature control. This unit features a stepless adjustable hot lid with pressure protection to prevent evaporation. It uses eight long-life Peltier heating units for consistent performance. Our thermal cycler supports USB drives for easy data transfer and updates.


$5,450.00

Catalog

Specifications

Capacity Double 48×0.2ml
Tube 0.1/0.2/0.5ml tube, 8 strips, 96 well plate
Reaction capacity 10 to 80μl, 10 to 120μl
Temperature range 0 to 105°C
Maximum ramp rate 5°C/s
Temperature uniformity ≤±0.2°C
Temperature accuracy ≤±0.1°C
Temperature display resolution 0.1°C
Temperature control method Block/tube
Ramping rate adjustable 0.1 to 5°C/s
Hold at 4°C Forever
Gradient type Normal
Gradient speed 1 to 30°C
Gradient temperature range 30 to 105°C
Hot lid temperature range 30 to 115°C
Maximum no. of steps 30
Maximum no. of cycles 200
Maximum no. of programs 10000 + (USB Flash)
Time increment/decrement 1s to 600s
Temperature increase/decrease 0.1 to 10°C
Pause function Yes
Auto data protection Yes
Touchdown function Yes
Long PCR function Yes
Language English
Mobile phone app Yes
LCD 8-inch, 800×600 pixels
Communication USB 2.0, WIFI
Power consumption 600W
Power supply 100 to 240VAC, 50/60Hz
Product dimension 390×270×255mm
Weight 9 kg

Features

  • High temperature accuracy
  • Fast heating/cooling rates
  • Graphical user interface
  • User-friendly touchscreen
  • Large storage capacity
  • GLP compliance reporting
  • Corrosion-resistant module

Applications

  • Dual Block Thermal Cycler NDBTC-100 is used to precisely amplify DNA sequences through controlled thermal cycling, enabling accurate genetic analysis and research. It is commonly applied in laboratories for tasks such as gene cloning, mutation detection, and diagnostic testing.

Ask Expert

FAQ for Dual Block Thermal Cycler NDBTC-100

1: Is the Dual Block Thermal Cycler NDBTC-100 easy to operate for first-time users?

The Dual Block Thermal Cycler features a user-friendly interface with a clear touchscreen display, making setup and experiment monitoring straightforward. Even if you are new to PCR, the preloaded standard templates help you quickly create protocols.

2: What happens if there is a power failure during a run?

The Dual Block Thermal Cycler is equipped with an automatic restart function that resumes the unfinished program once power is restored. This protects your samples and prevents the loss of valuable experiment time.

3: Can multiple PCR machines be controlled simultaneously?

Yes, with built-in WiFi connectivity, one mobile app or PC software can control multiple PCR machines at the same time. This feature is ideal if you are managing several instruments within a busy lab environment.

4: How often should the Dual Block Thermal Cycler NDBTC-100 be cleaned?

It is recommended to clean the thermal cycler’s exterior and sample blocks regularly, ideally after each major experiment or once a week. Using a soft cloth with mild detergent helps prevent dust and residue buildup, ensuring optimal performance.

5: What precautions should be taken while cleaning the hot lid?

You should gently clean the hot lid with a soft, lint-free cloth to avoid damaging its surface. Avoid using abrasive materials or harsh chemicals, as they can affect the pressure protection and sealing capability.

6: Does the Multi-Block Thermal Cycler support remote monitoring or data management?

Our Multi-Block Thermal Cyclers offer data storage options and connectivity through USB or network interfaces. This allows easy backup of protocols and remote monitoring for convenient experiment management.

7: Is the Multi-Block Thermal Cycler compatible with standard PCR consumables?

Yes, our Multi-Block Thermal Cycler supports commonly used tubes, strips, and microplates, ensuring compatibility with most existing laboratory supplies. This avoids the need for specialized consumables and reduces overall costs.

8: What maintenance is required for the Multi-Block Thermal Cycler?

Routine maintenance includes cleaning the blocks and ensuring the lid seals properly. Periodic calibration and software updates help maintain accuracy and performance over time.

9: How energy efficient is the Multi-Block Thermal Cycler?

Our Multi-Block Thermal Cyclers feature energy-saving modes that reduce power consumption during idle periods without affecting performance. This helps lower operating costs in busy laboratories.

Related Models Of Multi-Block Thermal Cycler

Labnics Multi-Block Thermal Cyclers are designed to perform simultaneous PCR amplification across multiple independent blocks. They ensure precise temperature control with uniform heating and cooling. These units use advanced heating elements for rapid thermal cycling and faster ramp rates. They feature a user-friendly interface equipped with a touch screen for easy operation. Our thermal cyclers include safety features to ensure secure and efficient use.